Tektronix 070-A830-51 Welding System User Manual


 
Operating Basics
2-46
AWG710 Service Manual
The waveform or pattern file contains only waveform and clock information.
When you load a waveform or pattern file, the output signal will use the current
instrument setup parameters.
To save you from doing a manual setup procedure each time you load a
waveform, the AWG710 Arbitrary Waveform Generator lets you save setup
parameters in a setup file. You can then restore the saved settings for use with
waveforms.
Do the following steps to save the current setup parameters:
1. Push SETUP (front)!Save/Restore (bottom)!Save Setup (side).
The Select Setup Filename dialog box appears.
2. Enter a setup file name.
The suffix .set will appear at the end of the file name.
3. Push the OK side button.
The setup information is saved to the designated file.
Do the following steps to restore the setup parameters from a file:
1. Select SETUP (front)!Save/Restore (bottom)!Restore Setup (side).
2. Enter or select the setup file name to load.
3. Push the OK side button to load the file and restore the setup parameters, or
push the Cancel side button to exit the restore process without loading the
setup file.
Saving and Restoring
Setup Parameters