Tektronix 070-A830-51 Welding System User Manual


 
Adjustment Procedures
5-4
AWG710 Service Manual
All the adjustment procedures are obtained through the Service menu which is a
submenu of the Utility menu. To enter this menu, you must enable the Service
mode using the switch on the A10 Connector board. Perform the following step:
Power on the waveform generator by pushing ON/STBY button while
pressing the service switch on the A10 Connector board. See Figure 5–1.
If you perform the adjustment procedure without removing the cabinet, you must
insert the adjustment tool (Table 5–4, Item 7) in the hole on the left side of the
waveform generator to engage the service switch.
Toggle the ON/STBY button to STBY to disable the Service mode.
Service switch
A10 Connector board
Adjustment tool
Figure 5-1: Accessing the service switch
Enabling Service Mode