Enterasys Networks XSR CLI Router User Manual


 
T1/E1 & T3/E3 Commands
XSR CLI Reference Guide 2-63
XSR(config)#controller t1 1/0
XSR(config-controller<T1-1/0>)#framing esf
XSR(config-controller<T1-1/0>)#linecode b8zs
XSR(config-controller<T1-1/0>)#clock source line
XSR(config-controller<T1-1/0>)#description “Acme’s T1”
ThefollowingexampledescribestheT3controllerinslot1,card2:
XSR(config)#controller t3 1/2
XSR(config-controller<T3-1/2/0>)#description “T3 Up at ACME”
dsu mode
For T3/E3 un-channelized controllers only
ThiscommandconfiguresanunchannelizedsubrateT3/E3porttoemulateaproprietaryData
ServiceUnit(DSU)scheme.TheXSRsupportsinteroperabilitywithawiderangeofthirdparty
DSUvendors.
LocalDSUmodeconfigurationmustmatchtheremoteconfiguration,soyoumustknowwhat
typeofDSUisconnectedto
theremoteporttodetermi neifitinteroperateswithaT3orE3NIM.
ThiscommandenablesinteroperabilitywithprovidersusingvariousT3orE3DSUstoprovision
theT3/E3line.
Syntax
dsu mode {digitallink | kentrox | larscom | adtran | verilink}
Syntax of the “no” Form
ThenoformofthiscommandsetstheDSUmodetothedefaultvalue:
no dsu mode
Mode
Controllerconfiguration: XSR(config-controller xx)#
Example
ThefollowingexampleconfigurestheT3controllerinslot1,card2withlinesourceclocking,M13
framing,inunchannelizedmode,withacablelengthof250feet,andDSUinteroperabilitymode
settoanAdtranDSU:
XSR(config)#controller<T3-1/2/0
XSR(config-controller<T3-1/2/0>)#no channelized
XSR(config-controller<T3-1/2/0>)#clock source line
digitallink
DigitallinkmodeconnectstheT3/E3controllertoaDigitalLink,CISCO,
orQuickEagleDSU.
kentrox
KentroxmodeconnectstheT3/E3controllertoaKentroxDSU.
larscom
LarscommodelinkstheT3controllertoaLarscomDSU.
adtran
AdtranmodeconnectstheT3controllertoanAdtranT3SU300.
verilink
VerilinkmodeconnectstheT3controllertoaVerilinkHDM2182.