National Instruments 321645c-01 Welding System User Manual


 
Chapter 2 Function Reference Config_DAQ_Event_Message
NI-DAQ FRM for PC Compatibles 2-76
©
National Instruments Corporation
Analog
positive
slope
triggering
5 Send a message when data from
any channel in chanStr
positively triggers on the
hysteresis window specified by
DAQTrigVal0 and
DAQTrigVal1, where
DAQTrigVal0
DAQTrigVal1. To positively
trigger, data must first go below
DAQTrigVal1 and above
DAQTrigVal0.
MIO and AI devices <AI>
Lab and 1200 Series devices <AI>
516 and LPM devices,
DAQCard-500/700 <AI>
Analog
negative
slope
triggering
6 Send a message when data from
any channel in chanStr
negatively triggers on the
hysteresis window specified by
DAQTrigVal0 and
DAQTrigVal1, where
DAQTrigVal0
DAQTrigVal1. To negatively
trigger, data must first go above
DAQTrigVal0 and below
DAQTrigVal1.
MIO and AI devices <AI>
Lab and 1200 Series devices <AI>
516 and LPM devices,
DAQCard-500/700 <AI>
Digital
pattern not
matched
7 Send a message when data from
any digital port in chanStr
causes this statement to be true:
data AND DAQTrigVal0 NOT
EQUAL DAQTrigVal1. Only
the lower word is relevant.
Lab and 1200 Series devices (except
an SCXI-1200 with remote SCXI)
<DIO>
DIO 6533 devices <DIO>
PC-DIO-24/PnP, DAQCard-DIO-24,
PC-DIO-96/PnP, PCI-DIO-96,
DAQPad-6507/6508 <DIO>
AT-MIO-16D, AT-MIO-16DE-10
<DIO>
Table 2-17.
DAQEvent Messages (Continued)
DAQEvent
Type
Code
Description
of Message
Usable Devices
<Usable Operation Families>