National Instruments 321645c-01 Welding System User Manual


 
Chapter 2 Function Reference AI_Mux_Config
©
National Instruments Corporation 2-11 NI-DAQ FRM for PC Compatibles
For the AT-MIO-64F-5, AT-MIO-64E-3, PCI-6031E (MIO-64XE-10), PCI-6033
(AI-64XE-10), and PCI-6071E (MIO-64E-1), you also must call
MIO_Config if you plan
to use AMUX-64T channels. Refer to the
MIO_Config function for further details.
Note Some of the digital lines of port 0 on the MIO or AI device with AMUX-64T
devices are reserved for AMUX device control. Any attempt to change the port or
line direction or the digital values of the reserved line causes an error. Table 2-2
shows the relationship between the number of AMUX-64T devices assigned to the
MIO or AI device and the number of digital I/O lines reserved. You can use the
remaining lines of port 0. On non-E Series devices, the remaining lines are
available for output only.
Table 2-2.
Port 0 Digital I/O Lines Reserved
Number of AMUX-64T Devices
Assigned to an MIO or AI Device
Port 0 Digital Lines
Reserved
0 none
1 lines 0 and 1
2 lines 0, 1, and 2
4 lines 0, 1, 2, and 3