National Instruments 321645c-01 Welding System User Manual


 
Chapter 2 Function Reference AO_Write
©
National Instruments Corporation 2-47 NI-DAQ FRM for PC Compatibles
AO_Write
Format
status = AO_Write (deviceNumber, chan, value)
Purpose
Writes a binary value to one of the analog output channels, changing the voltage produced at
the channel.
Parameters
Input
Parameter Discussion
chan is the analog output channel number.
Range: 0 or 1 for Lab and 1200 Series analog output and MIO devices.
0 through 5 for AT-AO-6.
0 through 9 for AT-AO-10.
0 through 47 for the VXI-AO-48XDC.
value is the digital value to be written to the analog output channel. value has several ranges,
depending on whether the analog output channel is configured for unipolar or bipolar
operations and on the analog output resolution of the device as shown in the following table.
Using This Function
AO_Write
writes value to the DAC in the analog output channel. If you configure the analog
output channel for immediate update, which is the default setting, the output voltage or
current changes immediately. Otherwise, the output voltage or current changes on a call to
AO_Update or the application of an external pulse.
Name Type Description
deviceNumber i16 assigned by configuration utility
chan i16 analog output channel number
value i16 digital value to be written
Device Bipolar Unipolar
Most devices –2,048 to +2,047 0 to +4,095
AT-MIO-16X, 16-bit E Series devices –32,768 to +32,767 0 to +65,535