National Instruments 321645c-01 Welding System User Manual


 
Chapter 2 Function Reference SCXI_Reset
NI-DAQ FRM for PC Compatibles 2-350
©
National Instruments Corporation
SCXI-1120, SCXI-1120D, SCXI-1121, and SCXI-1140:
If the module is operating in Multiplexed mode:
Channel 0 is selected.
Multiplexed channel scanning is disabled.
Module output is enabled if the module is cabled to a DAQ device.
Hold count is 1.
If the module is operating in Parallel mode:
All channels are enabled.
Track/hold signal is disabled.
SCXI-1124:
Sets the voltage range for each channel to 0 to 10 V. Writes a binary 0 to each DAC.
SCXI-1126:
Module range = 250 Hz
Module filter = 1 Hz
SCXI-1141:
If the module is in Multiplexed mode:
Channel 0 is selected.
Amplifier gains = 1.
Filters are bypassed.
MUXed scanning is disabled.
Module output is enabled if module is cabled to a DAQ device.
Autozeroing is disabled.
If the module is in Parallel mode:
All channels are enabled.
Amplifier gains = 1.
Filters are bypassed.
Autozeroing is disabled.
SCXI-1160:
Sets the current state information of relays in memory to unknown. No hardware
write takes place.
SCXI-1161:
Initializes all of the relays on the module to the Normally Closed position. It also
updates the software copy of the status maintained by the driver.