Mitsubishi Electronics QCPU Welding System User Manual


  Open as PDF
of 1204
 
App-25
8
8
8
8
A
6
7
8
Appendix1 OPERATION PROCESSING TIME
Appendix 1.3
Operation Processing Time of High Performance Model QCPU/Process CPU/Redundant CPU
Instruction Condition (Device)
Processing Time (µs)
Qn QnH QnPH QnPRH
OR < =
When not executed 0.24 0.10 0.10 0.10
When executed
In conductive status
0.24 0.10 0.10 0.10
In non-conductive status
0.24 0.10 0.10 0.10
LD <
In conductive status 0.24 0.10 0.10 0.10
In non-conductive status 0.24 0.10 0.10 0.10
AND <
When not executed 0.24 0.10 0.10 0.10
When executed
In conductive status
0.24 0.10 0.10 0.10
In non-conductive status
0.24 0.10 0.10 0.10
OR <
When not executed 0.24 0.10 0.10 0.10
When executed
In conductive status
0.24 0.10 0.10 0.10
In non-conductive status
0.24 0.10 0.10 0.10
LD > =
In conductive status 0.24 0.10 0.10 0.10
In non-conductive status 0.24 0.10 0.10 0.10
AND > =
When not executed 0.24 0.10 0.10 0.10
When executed
In conductive status
0.24 0.10 0.10 0.10
In non-conductive status
0.24 0.10 0.10 0.10
OR > =
When not executed 0.24 0.10 0.10 0.10
When executed
In conductive status
0.24 0.10 0.10 0.10
In non-conductive status
0.24 0.10 0.10 0.10
LDD =
In conductive status 0.55 0.24 0.24 0.24
In non-conductive status 0.39 0.17 0.17 0.17
ANDD =
When not executed 0.39 0.17 0.17 0.17
When executed
In conductive status
0.55 0.24 0.24 0.24
In non-conductive status
0.39 0.17 0.17 0.17
ORD =
When not executed 0.39 0.17 0.17 0.17
When executed
In conductive status
0.55 0.24 0.24 0.24
In non-conductive status
0.55 0.24 0.24 0.24
LDD < >
In conductive status 0.55 0.24 0.24 0.24
In non-conductive status 0.55 0.24 0.24 0.24
ANDD < >
When not executed 0.39 0.17 0.17 0.17
When executed
In conductive status
0.55 0.24 0.24 0.24
In non-conductive status
0.55 0.24 0.24 0.24
ORD < >
When not executed 0.39 0.17 0.17 0.17
When executed
In conductive status
0.55 0.24 0.24 0.24
In non-conductive status
0.55 0.24 0.24 0.24
LDD >
In conductive status 0.55 0.24 0.24 0.24
In non-conductive status 0.55 0.24 0.24 0.24
ANDD >
When not executed 0.39 0.17 0.17 0.17
When executed
In conductive status
0.55 0.24 0.24 0.24
In non-conductive status
0.55 0.24 0.24 0.24
ORD >
When not executed 0.39 0.17 0.17 0.17
When executed
In conductive status
0.55 0.24 0.24 0.24
In non-conductive status
0.55 0.24 0.24 0.24
LDD < =
In conductive status 0.55 0.24 0.24 0.24
In non-conductive status 0.55 0.24 0.24 0.24
ANDD < =
When not executed 0.39 0.17 0.17 0.17
When executed
In conductive status
0.55 0.24 0.24 0.24
In non-conductive status
0.55 0.24 0.24 0.24
ORD < =
When not executed 0.39 0.17 0.17 0.17
When executed
In conductive status
0.55 0.24 0.24 0.24
In non-conductive status
0.55 0.24 0.24 0.24