2-50
Table 2.30 Special Function Instructions (Continued)
Category
Instruction Symbol
Symbol Processing Details
Execution
Condition
Number of Basic Steps
Subset
See for Description
Point-by-
point
coordinate
data
SCL
• Executes scaling for the scaling
conversion data (16-bit data units)
specified by (S2) with the input value
specified by (S1), and then stores the
result into the device specified by (D).
The scaling conversion is executed
based on the scaling conversion data
stored in the device specified by (S2) an
up.
4-
7-330
SCLP
DSCL
• Executes scaling for the scaling
conversion data (32-bit data units)
specified by (S2) with the input value
specified by (S1), and then stores the
result into the device specified by (D).
The scaling conversion is executed
based on the scaling conversion data
stored in the device specified by (S2) an
up.
4-
DSCLP
X or Y
coordinate
data
SCL2
• Executes scaling for the scaling
conversion data (16-bit data units)
specified by (S2) with the input value
specified by (S1), and then stores the
result into the device specified by (D).
The scaling conversion is executed
based on the scaling conversion data
stored in the device specified by (S2)
and up.
4-
7-334
SCL2P
DSCL2
• Executes scaling for the scaling
conversion data (32-bit data units)
specified by (S2) with the input value
specified by (S1), and then stores the
result into the device specified by (D).
The scaling conversion is executed
based on the scaling conversion data
stored in the device specified by (S2)
and up.
4-
DSCL2P
SCL S1 S2 D
SCLP S1 S2 D
DSCL S1 S2 D
DSCLP S1 S2 D
SCL2 S1 S2 D
SCL2P S1 S2 D
DSCL2 S1 S2 D
DSCL2P S1 S2 D