Mitsubishi Electronics QCPU Welding System User Manual


  Open as PDF
of 1204
 
App-90
Category Instruction Condition (Device)
Processing Time (µs)
Q03UD(E)CPU
Q04/
Q06UD(E)HCPU
Q10/Q13/Q20/
Q26UD(E)HCPU
Min. Max. Min. Max. Min. Max.
Basic
instruction
LDE=
Single
precision
In conductive status 3.700 4.700 3.300 4.300 3.300 4.300
In non-conductive status
3.800 5.000 3.400 4.500 3.400 4.500
ANDE=
Single
precision
When not executed
When
executed
In conductive status 0.060 0.0285 0.0285
In non-conductive status 3.300 5.800 3.000 5.100 3.000 5.100
ORE=
Single
precision
When not executed 3.500 5.600 3.000 5.200 3.000 5.200
When
executed
In conductive status 0.060 0.0285
0.0285In non-conductive status 3.600 4.500 3.200 4.200
LDE< >
Single
precision
In conductive status 3.500 4.800 3.200 4.300
In non-conductive status 4.000 4.700 3.600 4.200
0.0285
ANDE< >
Single
precision
When not executed 3.900 4.500 3.500 4.000
When
executed
In conductive status 0.060 0.0285
0.0285In non-conductive status 3.300 5.100 3.000 4.800
ORE< >
Single
precision
When not executed 3.500 5.000 3.100 4.600
When
executed
In conductive status 0.060 0.0285
0.0285In non-conductive status 3.600 6.000 3.300 5.500
LDE>
Single
precision
In conductive status 3.500 5.800 3.100 5.300
In non-conductive status 3.800 5.000 3.300 4.600
0.0285
ANDE>
Single
precision
When not executed 3.700 4.900 3.300 4.400
When
executed
In conductive status 0.060 0.0285
0.0285In non-conductive status 3.500 4.700 3.100 4.200
ORE>
Single
precision
When not executed 3.600 4.500 3.100 4.000
When
executed
In conductive status 0.060 0.0285
0.0285In non-conductive status 3.600 5.100 3.300 4.600
LDE<=
Single
precision
In conductive status 3.500 4.800 3.200 4.500
In non-conductive status 3.800 5.600 3.400 5.200
0.0285
ANDE<=
Single
precision
When not executed 3.800 5.600 3.400 5.100
When
executed
In conductive status 0.060 0.0285
0.0285In non-conductive status 3.200 4.600 2.800 4.200
ORE<=
Single
precision
When not executed 3.500 5.000 3.100 4.500
When
executed
In conductive status 0.060 0.0285
0.0285In non-conductive status 3.700 5.800 3.400 5.400
LDE<
Single
precision
In conductive status 3.800 5.700 3.300 5.300
In non-conductive status 4.000 5.400 3.500 4.900
0.0285
ANDE<
Single
precision
When not executed 4.000 5.200 3.500 4.900
When
executed
In conductive status 0.060 0.0285
0.0285In non-conductive status 3.400 4.600 3.000 4.200
ORE<
Single
precision
When not executed 3.500 4.900 3.100 4.400
When
executed
In conductive status 0.060 0.0285
0.0285
In non-conductive status 3.600 5.200 3.300 4.900