5-42
DELTA(P)
5.3.10 Pulse conversions of direct outputs (DELTA(P))
DELTA(P)
Function
(1) Conducts pulse output of direct access output (DY) designated by .
If DELTA DY0 has been designated, the resulting operation will be identical to the ladder
shown below, which uses the SET/RST instructions.
[Ladder using the DELTA instruction] [Ladder using the SET/RST instructions]
[Operation]
(2) The DELTA (P) instruction is used by commands for leading edge execution for an intelligent
function module.
Operation Error
(1) In the following case, an operation error occurs, the error flag (SM0) turns ON, and an error
code is stored into SD0.
• A direct access output number designated by has exceeded the CPU module output
range. (Error code: 4101)
: Bit for which pulse conversion is to be conducted (bits)
Setting
Data
Internal Devices
R, ZR
J\
U\G
Zn Constants
Other
DY
Bit Word Bit Word
––
Basic
Process
High
performance
Redundant
Universal
Command
Command
DELTA
DELTAP
D
DELTA
D
DELTAP
D
D
D
X100
DY0DELTA
X100
DY0SET
DY0RST
X100
ON
OFF
DY0
ON
OFF
ON
END processing
DELTA DY0 DELTA DY0
D