Fujitsu CM25-00322-1E Saw User Manual


 
240
CHAPTER 4 MENUS
4.6.6 Sequence
"Sequence" displays the Sequence Window.
Sequence Window
The window that displays the sequence setting state opens. A sequence, latch, and delay count can be set
from this window.
This function can be used in the emulator (MB2141).
Setting the sequence
Select [Setup] from the shortcut menu of the Sequence Window.
Figure 4.6-8 Sequence Setting Dialog
-Level Select a level.(1-8)
-Event Select an event.(1-8/Timer)
-Jump Select a jump destination level. (1-8/END)
-Pass Count Set a pass count.
-Trace Control Select "Enable" or "Disable".
Setting the delay count
Select [Delay Count] from the shortcut menu of the Sequence Window.
Figure 4.6-9 Delay Count Setup Dialog Box
-Delay Count Set the delay count.
-Delay Count Break Select "Break" or "Not Break".