Barco R9850042 Tool Storage User Manual


 
20. OLite Display Configuration
20.2 Screen settings
Overview
•Overview
OSD functions
Tile Settings
View properties modules
20.2.1 Overview
Type
The type of the LED wall is indicated, OLite.
Measurement System
Type of measurement during manufacturing
Contrast
The light output of the screen in Nit value dependents on the wall type.
Image 20-2
Contrast setting, mode setting
To change the contrast:
Move the slide bar with the mouse. The value in the next to the slide bar will be adapted. or
Click in the digit window next to the slide bar and change the value by direct entering via the keyboard.
- OLiteDisplay:0to5000Nit
Contrast mode can be :
•Normal
Boosted : the contrast is internally increased to a higher value (up to 7000 Nit).
To select the contrast mode, click on the combo box and select the desired mode.
A warning message will be displayed.
It is recommended to use the boosted mode only with moving images.
The maximum Ambient temperature may not exceed 30°C. Therefore, enable the tem
perature moni-
toring (see "Monitoring Page", page 289 and follow topic "Temperature Control Set up", page 290)
Image 20-3
Contrast boost message
Contrast on RGB
Click on the RGB in the contrast selection. The slider changes t
o 3 sliders, one for each color.
The contrast can be adjusted for each color separately.
252
R5976380 XLITE TOOLSET 16/03/2005