Barco R9850042 Tool Storage User Manual


 
5. Wall Positioning Page
Image 5-21
Multiple selection via CTRL button
To physically see which tile is selected in the wall, switch Internal Patterns from Off to
On. The selected tile will display an internal pattern.
To scroll true the file list, use the red up or down arrows in the right bottom corner of
the Module list pane.
5.3.3 Cutout coordinates for DLite/SLite/ILite/OLite
What can be filled out
T
he start coordinates determine the position of each tile in the wall. These coordinates have to be entered
for each tile.
The size values determine the displayed resolution of the image. To calculate these values, starting from
the native tile resolution, use the following formulas:
Vertical Size = (image width / display width)* maximum tile resolution.
Horizontal Size = (image height / display height) * maximum tile resolution
The result of the calculation should be rounded to the lower digit. These result values for Vertical Size
a
nd Horizontal Size should be entered for each tile. When the values are lower that the tile resolution, the
image will be scaled (enlarged) to be displayed on the hole screen.
If you use the native resolution of the tile (depending on the type of wall) in stead of the calculated values,
the image will only be displayed on a part of the wall in stead of on the hole wall.
R5976380 XLITE TOOLSET 16/03/2005