SPI-4.2 Lite v4.3 User Guide www.xilinx.com 101
UG181 June 27, 2008
Sink Core Required Constraints
R
NET
"<snk_instance_name>/U0/pl4_lite_snk_core0/pl4_lite_snk_cal0/rs
clk_rst" MAXDELAY = 5.8 ns;
NET
"<snk_instance_name>/U0/pl4_lite_snk_reset01/snk_stat_clk_gen/
reset_out_i" MAXDELAY = 5.8 ns;
NET
"<snk_instance_name>/U0/pl4_lite_snk_reset01/snk_ff_clk_rst_gen
/reset_out_i” MAXDELAY = 5.8 ns
NET
"<snk_instance_name>/U0/pl4_lite_snk_reset01/snk_ff_clk_rst_gen
/fifo_reset_out_i" MAXDELAY = 5.8 ns;
NET
"<snk_instance_name>/U0/pl4_lite_snk_reset01/rdclk0_rst_gen/
fifo_reset_out_i” MAXDELAY = 5.8 ns;
NET
"<snk_instance_name>/U0/pl4_lite_snk_reset01/rdclk0_rst_gen/
reset_out_i" MAXDELAY = 5.8 ns;
These MAXDELAY values differ depending on target speed grade and core performance.
DCM and Static Alignment Constraints
DCM and BUFR (Virtex-4 and Virtex-5 devices only) constraints are needed to align
incoming data (RDat and RCtl) to its clock (RDClk) in the static alignment configuration.
In addition, the frequency of the DCM clock input must also be specified for complete
timing analysis. The following constraints are provided with the SPI-4.2 Lite core. You can
modify these constraints to meet your system requirements.
Phase Shift for DCM
The following constraints are used to align the incoming data (RDat and RCtl) to its clock
(RDClk) when global clocking is used. This is accomplished by changing the phase of the
I/O clock in relation to the data. The default PHASE_SHIFT value of 62 is the correct
nominal “PHASE_SHIFT,” assuming RDClk transitions at the same time as RDat and
RCtl inputs.
INST "<snk_instance_name>/U0/pl4_lite_snk_clk0/rdclk_dcm0"
CLKOUT_PHASE_SHIFT = FIXED;
INST "<snk_instance_name>/U0/pl4_lite_snk_clk0/rdclk_dcm0"
PHASE_SHIFT = 62;
Clock Delay in ISERDES
The following constraint applies to Virtex-4 and Virtex-5 devices only, and is needed to
align the incoming data (RDat and RCtl) to its clock (RDClk) at the ISERDES. The
alignment method can be used only when sink user clocking mode with regional clocking
distribution is selected. Alignment is accomplished by delaying the RDClk input in the
ISERDES using the “IOBDELAY” attribute. The default value in the UCF is the correct
“IOBDELAY” for the defined RDClk frequency, assuming RDClk transitions at the same
time as RDat and RCtl inputs. Each increment or decrement of the IOBDELAY value shifts
the RDat and RCtl input by 75 ps forwards or backwards. See the Virtex-4 Data Sheet and
the Virtex-5 Data Sheet for more information.