PL ACE
S)
Figure 4.
A6A4
Second Converter Replacement
A6A6 First Converter Replacement
Note
For location of hardware and cables referred to in this procedure, see Figure 5.
Removal
1. Remove ac line cords, IF-Display Section, and RF Section top cover.
2. Remove two screws
@
to release A6A6 First Converter from A6 RF Module. Disconnect
connectors
@
from A6A6 First Converter.
Installation
3. Position new A6A6 First Converter in RF Module and reconnect connectors
0.
Reinstall
two screws
0.
4. Replace RF Section top cover. Attach IF-Display Section to RF Section. Reconnect ac line
cords.
A6 9