4 POSITIONING SIGNALS
(6) Servo error reset command (M3208+20n)
(a) This command is used to clear the servo error code storage register of an
axis for which the servo error detection signal has turn on (M2408+20n:
ON), and reset the servo error detection signal (M2408+20n).
Servo error reset command
(M3208+20n)
Servo error detection signal
(M2408+20n)
Servo error code storage
register
ON
OFF
OFF
ON
00
**
** : Error code
(b) If an error reset is executed during the temporary stop (M4003+10n) by the
temporary stop command (M4400+10n) at the automatic start or if an error
reset is executed during a block stop by M00/M01, the Motion program
operation state is reset.
The SVST instruction must be executed in the next strat. (Re-start is not
possible.)
Automatic start
(M4002+10n)
Temporary stop (M4003+10n)
Temporary stop command
(M4400+10n)
Block stop by M00/M01
OFF
ON
Start accept flag (M2001+n)
Servo error reset command
(M3208+20n)
Motion program (Axis
designation program) start
(c) When the error reset command is turned on at the automatic start
(M4002+10n: ON), the above reset processing is executed after the stop
processing by temporaty stop command (M4400+10n).
REMARK
Refer to APPENDIX 1 for details on the minor error code, major error code and