Mitsubishi Electronics Q173HCPU/Q172HCPU Work Light User Manual


 
7 - 72
7 AUXILIARY AND APPLIED FUNCTIONS
(6) The command in-position signal for FIN signal wait function is output as below.
(a) When the automatic deceleration is started by positioning to the executed
point (including the last point) during FIN signal wait.
If the difference between the positioning address (command position) of
executing point and the machine value reaches within the command in-
position range during FIN signal wait deceleration, the command in-position
signal (M2403+20n) turns on.
When the axis transits to the next point, the command in-position signal turns
off.
1
FIN signal
(M3219+20n)
M-code outputting
(M2419+20n)
1110
Point
M-code
(D13+20n)
2
FIN wait
Command in-position
(M2403+20n)
Automatic deceleration
Command in-position setting value
(b) When the axis transits to the next point without automatic deceleration by
positioning to the executing point during FIN signal wait.
If the axis transits to the next point without automatic deceleration, the
command in-position signal does not turn on.
FIN signal
(M3219+20n)
M-code outputting
(M2419+20n)
1110
Point
M-code
(D13+20n)
Command in-position
(
M3203+20n
)
Deceleration component of point 1
Deceleration component of point 2
21
3
12
Deceleration component of point 2
Deceleration component of point 3