7 AUXILIARY AND APPLIED FUNCTIONS
[Cautions]
(1) When the stop command (external, M3200+20n, M3201+20n), cancel signal or
skip signal is input, the M-code outputting signal turns OFF.
(2) When M-code is set at the end point, positioning ends after the FIN signal has turn
OFF to ON to OFF.
(3) Transition of point for the FIN signal wait function is executed with the command
before acceleration/deceleration. (Refer to Fig in (6) (b).)
(4) M-code outputting signal is output to all interpolation axes at the interpolation
control. In this case, turn on the signal for one of the interpolation axes.
However, the FIN signal for the high-speed oscillation execution axis is ignored.
(5) When the FIN signal for any one of the interpolation axes is ON, the M-code
outputting signal is not output if the FIN wait function is executed.
1
FIN signal (1st axis)
(M3219)
M-code outputting
(M2419+20n)
1110
Point
M-code
(D13+20n)
2
FIN wait
Since FIN signal for second axis is ON, M-code
outputtin
g
si
g
nal does not turn ON.
When FIN signal for second axis turns OFF,
M-code outputting signal turns ON.
Example: When the FIN waiting function for point 1 is executed while the second axis
turns on.
FIN signal (2nd axis)
(M3239)