Mitsubishi Electronics Q173HCPU/Q172HCPU Work Light User Manual


 
6 - 35
6 MOTION PROGRAMS FOR POSITIONING CONTROL
• For NOT
The following table indicates the data type combinations and conversion methods
for NOT.
Operation result = operator [Data 1]
Operator denotes NOT.
For logical and shift operations, operation including the 64-bit floating-point type
cannot be performed. (Error "560 : format error")
No. Operation result Data 1 Remarks
1
#n (16 bit)
No conversion
2
#nL, #n:L (32 bit)
32-bit data is converted into 16-bit data.
Error occurs if conversion result exceeds 16-bit range. (Error : 531)
3
#n (16 bit)
No conversion
#nF, #n:F (64 bit)
Operation cannot be performed.
Operation disabled
4
#n (16 bit)
16-bit data is converted into 32-bit data.
5
#nL, #n:L (32 bit)
No conversion
6
#nL, #n:L (32 bit)
(32 bit)
No conversion
#nF, #n:F (64 bit)
Operation cannot be performed.
Operation disabled
n : Indicates variable number or device number