Toshiba VF-AS1 Welding System User Manual


 
K-11
E6581301
11
[11] Preset speed operation frequency (8~15) Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Wr
ite during
running
Vector control
PM
control
V/f Reference
Speed
control
Torque
control
H
0287
Preset speed operation
frequency 8
NN~WN Hz 0.1/0.01 0.0 Enabled Ɣ/Ɣ - Ɣ Ɣ 5. 12
H
0288
Preset speed operation
frequency 9
NN~WN Hz 0.1/0.01 0.0 Enabled Ɣ/Ɣ - Ɣ Ɣ 5. 12
H
0289
Preset speed operation
frequency 10
NN~WN Hz 0.1/0.01 0.0 Enabled Ɣ/Ɣ - Ɣ Ɣ 5. 12
H
0290
Preset speed operation
frequency 11
NN~WN Hz 0.1/0.01 0.0 Enabled Ɣ/Ɣ - Ɣ Ɣ 5. 12
H
0291
Preset speed operation
frequenc
y 12
NN~WN Hz 0.1/0.01 0.0 Enabled Ɣ/Ɣ - Ɣ Ɣ 5. 12
H
0292
Preset speed operation
frequency 13
NN~WN Hz 0.1/0.01 0.0 Enabled Ɣ/Ɣ - Ɣ Ɣ 5. 12
H
0293
Preset speed operation
frequency 14
NN~WN Hz 0.1/0.01 0.0 Enabled Ɣ/Ɣ - Ɣ Ɣ 5. 12
H
0294
Preset s
peed operation
frequency 15
(
Forced operation frequency
)
NN~WN Hz 0.1/0.01 0.0 Enabled Ɣ/Ɣ - Ɣ Ɣ 5. 12
[12] Tripless intensification setup [1/2] Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector control
PM
control
V/f Reference
Speed
control
Torque
control
EH
0300
PWM carrier frequency
1.0~16.0kHz
(2.5
~
8.0kHz)
*
1
0.1/0.1
*2
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
5. 17
WXU
0301 Auto-restart control selection
0:Disabled
,
1:At auto
-
restart
2:ST ON/OFF switching, 3:1+2, 4:Starting
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 5. 18.1
WXE
0302
Regenerative power
ride-through control
0:Disabled
,
1:Power ride
-
through
2:Deceleration stop during power failure
3:Synchronized deceleration/acceleration
(synchronized acceleration/deceleration signal)
4:Synchronized deceleration/acceleration
(synchronized acceleration/deceleration signal+power
failure)
1/1 0 Disabled Ɣ/Ɣ -/- Ɣ Ɣ 5. 18. 2
H
0303
Retry selection
0:Deselect, 1
-
10 times
1/1
0
Enabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
6. 14. 1
RD
0304 Dynamic braking selection
0:Disabled
1:Enabled (braking resistance overload detect)
2:
Enabled
(braking resistance overload not detect)
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 5. 19
H
0305 Overvoltage limit operation
0:
Enabled
1:Disabled
2:Enabled (quick deceleration)
3:
Enabled
(dynamic quick deceleration)
1/1 2 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 14. 2
This parameter moves to a fundamental parameter. *1: For 200V-55/75kW models and 400V-90kW to 400V-500kW models, the carrier frequency is between 2.5 and 8.0kHz inclusive.
*2: Default values vary depending on the capacity. See the table of K-48.