Toshiba VF-AS1 Welding System User Manual


 
K-39
E6581301
11
[Contents of monitor displays] Sensorless vector/vector with sensor (Ɣ: valid, -: invalid)
Communi
cation No.
Function
Unit
(Commun
ication)
Monitor output
selection
Trip
retention
Meter
output
selection
Speed
control
Torque
control
PM control V/f Reference
- Standard monitor - H * 1
8.2.1
Contents of status monitor display
FE31 Pattern operation group selection -
at a pattern
operation
ż - Ɣ/Ɣ - Ɣ Ɣ
FE32
Number of times to repeat current
pattern
1
at a pattern
operation
ż - Ɣ/Ɣ - Ɣ Ɣ
FE33
Pattern operation - number of preset
speeds
1
at a pattern
operation
ż - Ɣ/Ɣ - Ɣ Ɣ
FE34
Remaining time of current pattern
operation
1
at a pattern
operation
ż - Ɣ/Ɣ - Ɣ Ɣ
FE01 Status (rotation direction) - Fixed ż - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
- Status monitor 1 -
H
* 1
- Status monitor 2 -
H
* 1
- Status monitor 3 - H * 1
- Status monitor 4 -
H
* 1
- Status monitor 5 -
H
* 1
- Status monitor 6 - H * 1
- Status monitor 7 -
H
* 1
- Status monitor 8 -
H
* 1
FE00 Output frequency monitor 0.01Hz
when tripped when tripped
- Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE06 Input terminal information - Fixed ż - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
- Input terminal information (optional) - Fixed ż - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
- Input terminal information (optional) - Fixed ż - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE07 Output terminal information - Fixed ż - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
- Output terminal information (optional) - Fixed ż - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE08 CPU1 version 1 Fixed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE73 CPU2 version - Fixed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE10 Past trip 1 - Fixed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE11 Past trip 2 - Fixed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE12 Past trip 3 - Fixed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE13 Past trip 4 - Fixed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE79 Part replacement alarm information - Fixed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE14 Cumulative operation time 1h Fixed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
*1: Status in a trip may not be held depending on selected function. Refer to next page; [Monitor FM/AM/pulse output function selection].