Toshiba VF-AS1 Welding System User Manual


 
K-19
E6581301
11
[21] Adjustment parameters [2/2] Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector control
PM
control
V/f Constant
Reference
Speed
control
Torque
control
H
0469
Overvoltage limit constant
0:
Automatic
, 1~1000ms
1/1
0
Disabled
-
/
-
-
/
-
-
Ɣ
6.14.2
H
0470
VI/II input bias
0~255
1/1
*2
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 28
H
0471
VI/II input gain
0~255
1/1
*2
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 28
H
0472
RR
/S4
input bias
0~255
1/1
*2
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 28
H
0473
RR
/S4
input gain
0~255
1/1
*2
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 28
H
0474
RX input bias
0~255
1/1
*2
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 28
H
0475
RX input gain
0~255
1/1
*1
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 28
H
0476
Optional
A
I
1 input bias
0~255
1/1
*1
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 28
H
0477
Optional
A
I
1 input gain
0~255
1/1
*1
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 28
H
0478
Optional
A
I
2 input bias
0~255
1/1
*1
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 28
H
0479
Optional
A
I
2 input gain
0~255
1/1
*1
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 28
H
0490
Factory spe
cific coefficient 2
-
1/1
0
Disabled
-
-
-
-
-
H
0491
Auto-restart method selection
0
Searching speed method 1
(factory setting)
1
Searching speed method
2
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ - Ɣ 5.18.1
H
0492
V/f
adjustment
ratio
10
100%
1/1
100
Enabled
-
/
-
-
/
-
-
Ɣ
6.3.6
H
0495
M
ax
output
voltage modulation
rate
0:
Standard
1
:Straight
100%
2:102.5%
3:105%
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6.27.3
H
0498
PM motor constant 1 (d axis
inductance)
0~100%
0.1/0.1 10.0 Disabled - - Ɣ - 6. 29
H
0499
PM motor
constant 2 (q axis
inductance)
0~100%
0.1/0.1 10.0 Disabled - - Ɣ - 6. 29
*1: Settings vary from unit to unit. Even if V[R is set to , no change is made to these values.
[22] Acceleration/deceleration 2 [1/2] Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector control
PM
control
V/f Constant
Reference
Speed
control
Torque
control
H
0500 Acceleration time 2 0.1~6000 sec. 0.1/0.1 *2 *1 Enabled Ɣ/Ɣ - Ɣ Ɣ 6. 30. 1
H
0501
Deceleration time 2 0.1~6000 sec.
0.1/0.1 *2
*1
Enabled
Ɣ
/
Ɣ
-
Ɣ
Ɣ
6. 30. 1
H
0502 Acceleration/deceleration 1 pattern 0:Straight, 1:S-pattern 1, 2:S-pattern 2 1/1 0 Enabled Ɣ/Ɣ - Ɣ Ɣ 6. 30. 1
H
0503 Acceleration/deceleration 2 pattern 0:Straight, 1:S-pattern 1, 2:S-pattern 2 1/1 0 Enabled Ɣ/Ɣ - Ɣ Ɣ 6. 30. 1
H
0504
Panel acceleration/deceleration
selection
1:Acceleration/deceleration 1
2:Acceleration/deceleration 2
3:Acceleration/deceleration 3
4:Acceleration/deceleration 4
1/1 Enabled Ɣ/Ɣ - Ɣ Ɣ 6. 30. 1
H
0505
Acceleration/deceleration
switching frequency 1
0.0~HJ Hz 0. 1/0.01 0.0 Enabled Ɣ/Ɣ - Ɣ Ɣ 6. 30. 1
H
0506
Acceleration S-pattern lower
limit adjustment
0~50%
1/1 10 Enabled Ɣ/Ɣ - Ɣ Ɣ 6. 30. 1
H
0507
Acceleration S-pattern upper
limit adjustment
0~50%
1/1 10 Enabled Ɣ/Ɣ - Ɣ Ɣ 6. 30. 1
H
0508
Deceleration S
-
pattern lower
limit adjustment
0~50%
1/1 10 Enabled Ɣ/Ɣ - Ɣ Ɣ 6. 30. 1
*1: Default values vary depending on the capacity. See the table of K-48.
*2: Changing the parameter VR enables to set to 0.01 sec. (adjustment range: 0.01~600.0 sec.).