[28] Operation panel parameters [1/3] Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector control
PM
control
V/f Constant
Reference
Speed
control
Torque
control
H
0700
Parameter wr
ite protect
selection
0:Permit
1:Prohibit
1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 36. 1
FURW
0701
Current/voltage unit selection
0:%, 1:A (ampere)/V (volt)
1/1
0
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
5. 15
H
0702
Frequency free unit display
magnification
0.00:OFF, 0.01~200.0 0.01/0.01 0.00 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 36. 2
H
0703
Frequency free unit conversion
selection
0:All frequencies display free unit conversion
1:PID frequencies free unit conversion
1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 36. 2
H
0705
Free unit display gradient
chara
cteristic
0:Negative inclination (downward slope)
1:Positive inclination (upward slope)
1/1 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 36. 2
H
0706
Free unit display bias
0.00~
HJ
Hz
0.
0
1/0.01
0.00
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 36. 2
H
0707
Changing step selection 1
0.00:D
isabled, 0.01~
HJ
Hz
0.
0
1/0.01
0.00
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 36. 3
H
0708
Changing step selection 2
0:Disabled, 1~255
1/1
0
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 36. 3
H
070
9
S
tandard
monitor hold function
0
:Real time, 1:Peak hold, 2:Minimum hold
1/1
0
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
8. 3
H
0710
Standard monitor display
selection
0~80 *1 1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 8. 3
H
0711
Status monitor 1 display
selection
Ditto 1/1 1 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 8. 3
H
0712
Status monitor 2 display
selection
Ditto 1/1 2 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 8. 3
H
0713
Status monitor 3 display
selection
Ditto 1/1 3 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 8. 3
H
0714
Status monitor 4 display
selection
Ditto 1/1 4 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 8. 3
H
0715
Status monitor 5 display
selection
Ditto 1/1 8 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 8. 3
H
0716
Status monitor 6 display
selection
Ditto 1/1 16 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 8. 3
H
0717
Status monitor 7 display
selection
Ditto 1/1 15 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 8. 3
H
0718
Status monitor 8 display
selection
Ditto 1/1 14 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 8. 3
H
0719
Operation command clear
selection
0
When s
tandby
terminal
(ST) is
OFF
, clear panel
operation command
1When standby terminal (ST) is OFF, remain
operation command
2When standby terminal (ST) is OFF or
undervoltage alarm occurs, clear operation
command
1/1 1 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 36. 5
H
0721
Operation panel stop pattern
selection
0:Deceleration stop
1:Coast
stop
1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 36. 6
This parameter moves to a fundamental parameter. *1: For the adjustment range, see the table on page K-40.