E6581301
11
K-38
[30] My function [5/5] Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector control
PM
control
V/f Constant
Reference
Speed
control
Torque
control
H
0962 Analog input function target 21
0:Disabled
1:VI/II
2:RR/S4
3:RX
4:Optional AI1+, Optional AI1-
5:Optional AI2
6:
Internal memory
2
1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0964
Analog
function
assigned object
21
0~10 1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0965 Monitor output function target 11
2000~2099:FD00~FD99
3000~3099:FE00~FE99
1/1 2000 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0966
Monitor output
function
command
11
0:Normal monitor, 1:Max. value, 2:Min. value 1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0967
Monitor output
function target
21
2000~2099:FD00~FD99
3000~3099:FE00~FE99
1/1 2000 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0968
Monitor output
function
command
21
0:Normal monitor, 1:Max. value, 2:Min. value 1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0969
Monitor output
function target
31
2000~2099:FD00~FD99
3000~3099:FE00~FE99
1/1 2000 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0970
Monitor output
function
command
31
0:Normal monitor, 1:Max. value, 2:Min. value 1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0971
Monitor output
function target
41
2000~2099:FD00~FD99
3000~3099:FE00~FE99
1/1 2000 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0972
Monitor output
function
command
41
0:Normal monitor, 1:Max. value, 2:Min. value 1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0973
Virtual input terminal selection 1
0
~
155 *2
1/1
0
Disabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
*1
H
0974
Virtual input terminal selection
2
0
~
155 *2
1/1
0
Disabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
*1
H
0975
Virtual input terminal selection
3
0
~
155 *
2
1/1
0
Disabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
*1
H
0976
Virtual input terminal selection
4
0
~
155 *2
1/1
0
Disabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
*1
H
0977 My function selection
0:Disabled
1:My function + permission signal
2:
My function always ON
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
*1: For details, refer to Instruction Manual (E6581335) specified in Section 6.42. *2: For the adjustment range, see the table on page K-43.
[31] Travenirse function Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector control
PM
control
V/f Constant
Reference
Speed
control
Torque
control
H
0980 Traverse selection
0:
Disabled
1
:
E
nabled
1/1 0 Disabled Ɣ/Ɣ - Ɣ Ɣ *1
H
0981
Traverse acceleration time
0.1~120
.0
sec.
0.1/0.1
25.0
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
*1
H
0982
Traverse deceleration time
0.1~120
.0
sec.
0.1/0.1
25.0
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
*1
H
0983
Traverse step
0.0~25.0%
0.1/0.1
10.0
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
*1
H
0984
Traverse jump step
0.0~50.0%
0.1/0.1
10.0
Enabled
Ɣ/Ɣ
-
Ɣ
Ɣ
*1
*1: For details, refer to Instruction Manual (E6581337) specified in Section 6.42.