E6581301
L-2
12
2) Standard specifications (large capacity types) [Note 1]
Item
Specification
Voltage class
200V class
Applicable motor (kW)
55 75
Applicable motor (HP)
75 100
Rating
Type VFAS1-
Form 2550P 2750P
Output capacity
(kVA) [Note 2]
84 109
Output current
(A)
221 285
Output voltage Three-phase 200V~240V (The maximum output voltage is equal to the input supply voltage.)
Overload
current rating
150%-1 minute, 165%-2 sec.
Electrical
braking
Dynamic braking
circuit
Built-in dynamic braking drive circuit
Dynamic braking
resistor
An external braking resistor (optional)
Rating: Refer to 5.19.
Power
supply
Voltage-frequency
[Note 3]
Three-phase 200~240V-50/60Hz
Allowable
fluctuation
Voltage + 10% - 15% [Note 4] Frequency ±5%
Protective method
(IEC60529)
IP00 Open type [Note 5]
Cooling method Forced air-cooled
Cooling fan noise (dBA)
61 72
Color RAL7016
EMC filter External filter (optional)
DC reactor Attached DC reactor
Item
Specification
Voltage class
400V class
Applicable motor (kW)
90 110 132 160 200 220 280 355 400 500
Applicable motor (HP)
125 150 200 250 300 350 450 550 600 700
Rating
Type VFAS1-
Form 4900PC 4110KPC 4132KPC 4160KPC 4200KPC 4220KPC 4280KPC 4355KPC 4400KPC 4500KPC
Output capacity
(kVA) [Note 2]
136 164 197 239 295 325 419 511 578 717
Output current
(A)
179 215 259 314 387 427 550 671 759 941
Output voltage Three-phase 380V~480V (The maximum output voltage is equal to the input supply voltage.)
Overload
current rating
150%-1 minute, 165%-2 sec.
Electrical
braking
Dynamic
braking circuit
Built-in dynamic braking drive circuit External dynamic braking circuit (optional)
Dynamic braking
resistor
An external braking resistor (optional)
Rating: Refer to 5.19.
Power
supply
Voltage-frequency
[Note 3]
[Note 6]
Three-phase 380~440V-50Hz
Three-phase 380~480V-60Hz
Allowable
fluctuation
Voltage + 10% - 15% [Note 4] Frequency ±5%
Protective method
(IEC60529)
IP00 Open type [Note 5]
Cooling method Forced air-cooled
Cooling fan noise (dBA)
61 72 73 73 76 76 76 76 76 78
Color RAL7016
EMC filter Built-in
DC reactor Attached DC reactor
Note 1: For 200V-55kW, 400V-90kW or larger model, be sure to install DC reactor.
However, this is unnecessary for DC input specifications.
Note 2: Capacity is calculated at 220V for the 200V models and at 440V for the 400V models.
Note 3: An external power supply backup available (optional) (Type: CSP002Z)
Note 4: ±10% when the inverter is used continuously (load of 100%).
Note 5: Models, 200V-18.5kW or more and 400V-22kW or more, do not have wiring port covers. They have large
openings, but there is no space to bend the external cables inside the unit.
Note 6: Three-phase 380~480V-50/60Hz for 4900PC