5
[Terminal FM-related parameters]
Title Function Adjustment range
Adjustment
level
Default setting
HOUN
FM terminal meter
selection
:Output frequency
:Frequency command value
:Output current
:Input voltage (DC detection)
:Output voltage
:Compensated frequency *2
:Speed feedback (real-time value)
:Speed feedback (1 second filter)
:Torque
:Torque command
:Torque current
:Exiting current
:PID feedback value
:Motor overload factor (OL2 data)
:Inverter overload factor (OL1 data)
:
Regenerative braking resistance overload factor (OLr data)
:Regenerative braking resistor load factor (% ED)
:Input power
:Output power
:Optional AI2 input
:RR/S4 input
:VI/II input
:RX input
:Optional AI1 input
:FM output (Do not select this option.)
:AM output
:Fixed output 1
:Communication data output
:Fixed output 2
:Fixed output 3
:Cumulative input power
:Cumulative output power
:Gain display
~:My function monitor 1~4
:Signed output frequency
:Signed frequency command value
:Signed compensated frequency
:Signed speed feedback (real-time value)
:Signed speed feedback (1 second filter)
:Signed torque
:Signed torque command
:Signed torque current
:Signed PID feedback value
:Signed RX input
:Signed optional AI1 input
~:Signed fixed output 1~3
~:Function none
: MON1 (Expansion I/O card2 option)
: MON2 (Expansion I/O card2 option)
: RP (Expansion I/O card2 option)
(a)
(a)
(b)
(c)
(c)
(a)
(a)
(a)
(d)
(d)
(b)
(b)
(a)
(a)
(a)
(a)
(a)
(b)
(b)
(a)
(a)
(a)
(a)
(a)
(a)
(a)
(a)
(a)
*1
(a)
(a)
(a)
(a)
(a)
(d)
(d)
(b)
(a)
(a)
(a)
(a)
(a)
(a)

HO
FM terminal meter
adjustment
*3
H
Constant at the
time of filtering *4
msec, msec~ msec 
H
FM voltage/current
output switching
:Voltage output (0~10V), :Current output (0~20mA)
H
FM output gradient
characteristic
:Negative gradient (downward-sloping),
:Positive gradient (upward-sloping)
H
FM bias adjustment ~ %

H
FM output filter
:No filter, :Filter approx. 10ms
:Filter approx. 15ms, :Filter approx. 30ms
:Filter approx. 60ms, :Filter approx. 120ms
:Filter approx. 250ms, :Filter approx. 500ms
:Filter approx. 1s

*1: Monitor adjustment level selected.
*2: “Compensated frequency” refers to the frequency actually sent from an inverter to the motor connected.
*3: Default setting value is adjusted for connection of frequency meters "QS60T".
(Between FM and CCA: Approx. 3.6V)
*4: The output current, input voltage, output voltage, compensated frequency, speed feedback (real-time value) torque, torque
current and exciting current output (FM/AM/pulse and monitor output) can be filtered.