E6581301
11
K-28
[28] Operation panel parameters [2/3] Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
V
ector control
PM
control
V/f Constant
Reference
Speed
control
Torque
control
H
0725
Operation panel torque
command
-250~250% 1/0.01 0 Enabled - Ɣ/Ɣ - - 6. 36. 7
H
0727
Operation panel tension torque
bias
-250~250% 1/0.01 0 Enabled - Ɣ/Ɣ - - 6. 36. 8
H
0728
Operation panel load sharing
gain
0~250% 1/0.01 100 Enabled - Ɣ/Ɣ - - 6. 36. 8
H
0729
Operation panel override
multiplication gain
-100~100% 1/0.01 0 Enabled Ɣ/Ɣ - Ɣ Ɣ 6. 34
H
0730
Operation panel frequency
setting prohibition selection
0:Permit
1:Prohibit
1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 36. 1
H
0731
LED/LCD panel cable breakage
detection selection
0ᲴDisconnection detection (GTT trip)
1ᲴNo disconnection detection (retain operation
command)
1/1 1 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6.33.26
H
0734
Operation panel emergency
stop operation prohibition
selection
0:Permit
1:Prohibit
1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 36. 1
H
0735
Operation panel reset operation
prohibition selection
0:Permit
1:Prohibit
1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 36. 1
H
0736
P
rohibition
of change of
EOQF/HOQF during
operation
0:Permit
1:Prohibit
1/1 1 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 36. 1
H
0737 All key operation prohibition
0:Permit
1:Prohibit
1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 36. 1
H
0740
Trace selection
0:Deselect, 1:At trip
ping, 2:At triggering
1/1
1
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 37
H
0741
Trace cycle
0:
4
ms, 1:
2
0ms, 2:100ms, 3:1s, 4:10s
1/1
2
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 37
H
0742
Trace data 1
0~49
1/1
0
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 37
H
0743
Trace data 2
0~49
1/1
1
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 37
H
0744
Trace data 3
0~49
1/1
2
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 37
H
0745
Trace data 4
0~49
1/1
3
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 37
H
0748
Integrating wattmeter retention
selection
0:Disabled
1:Enabled
1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 38
H
0749
Integrating wattmeter display
unit selection
0:
1=1kWh
1:1=10kWh
2:1=100kWh
3:1=1000kWh
4
:
1=10000kWh
1/1 *2 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 38
H
0750 EASY key function selection
0:
Quick
mode/
standard
setting mode switching
function
1:
Shortcut key
:Pressing for 2 sec. to record the
parameter, pressing normally to jump
to recorded parameter (first jump to
the 1st history)
2:Operation panel/remote key:Operation panel by
ON
3:Monitor
p
eak minimum
h
old trigger
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 5. 22
*1: The communication number of the parameter is used for this setting.
*2: Default values vary depending on the capacity. See the table of K-48.