Cisco Systems A9014CFD Router User Manual


 
10-17
Cisco ASR 901 Series Aggregation Services Router Software Configuration Guide
OL-23826-09
Chapter 10 Configuring Ethernet OAM
Step 4
cos cos-value (Optional) Set a class of service value for the operation.
Step 5
frequency seconds (Optional) Set the rate at which the IP SLA operation
repeats. The range is from 1 to 604800 seconds; the default
is 60 seconds.
Step 6
history history-parameter (Optional) Specify parameters for gathering statistical
history information for the IP SLA operation.
Step 7
owner owner-id (Optional) Configure the SNMP owner of the IP SLA
operation.
Step 8
request-data-size bytes (Optional) Specify the protocol data size for an IP SLA
request packet. The range is from 0 to the maximum size
allowed by the protocol being used; the default is 66 bytes.
Step 9
tag text (Optional) Create a user-specified identifier for an IP SLA
operation.
Step 10
threshold milliseconds (Optional) Specify the upper threshold value in
milliseconds (ms0 for calculating network monitoring
statistics. The range is 0 to 2147483647; the default is
5000.
Step 11
timeout milliseconds (Optional) Specify the amount of time in ms that the IP
SLA operation waits for a response from its request packet.
The range is 0 to 604800000; the default value is 5000.
Step 12
exit Return to global configuration mode.
Step 13
ip sla schedule operation-number [ageout seconds]
[life {forever | seconds}] [recurring] [start-time
{hh:mm {:ss} [month day | day month] | pending |
now | after hh:mm:ss}]
Schedule the time parameters for the IP SLA operation.
operation-number—Enter the IP SLA operation
number.
(Optional) ageout seconds—Enter the number of
seconds to keep the operation in memory when it is not
actively collecting information. The range is 0 to
2073600 seconds. The default is 0 seconds.
(Optional) life—Set the operation to run indefinitely
(forever) or for a specific number of seconds. The
range is from 0 to 2147483647. The default is 3600
seconds (1 hour)
(Optional) recurring—Set the probe to be
automatically scheduled every day.
(Optional) start-time—Enter the time for the
operation to begin collecting information:
To start at a specific time, enter the hour, minute,
second (in 24-hour notation), and day of the
month.
Enter pending to select no information collection
until a start time is selected.
Enter now to start the operation immediately.
Enter after hh:mm:ss to show that the operation
should start after the entered time has elapsed.
Command Purpose