Configuring EEP Applet Using CLIs
To configure EEP applet, complete the following steps:
Prerequisites
One switch virtual interface (SVI) or bridge domain is required per physical link.
One EEM script is required per physical link.
Note The EEM script configures the metric on the microwave link and adjusts the QoS policy based on the
Ethernet event parameters. You can download the scripts from the following location:
SUMMARY STEPS
1. enable
2. configure terminal
3. event manager applet applet-name
4. event tag event-tag ethernet microwave clear-sd {interface type number}
5. event tag event-tag ethernet microwave sd {interface type number} threshold mbps
6. action action-id set variable-name variable-value
7. action action-id cli command cli-string
8. action action-id cli command cli-string
9. exit
DETAILED STEPS
Command Purpose
Step 1
enable
Example:
Router> enable
Enables privileged EXEC mode.
Enter your password if prompted.
Step 2
configure terminal
Example:
Router# configure terminal
Enters global configuration mode.
Step 3
event manager applet
applet-name
Example:
Router(config)# event manager applet
ACM61
Registers an applet with the Embedded Event Manager (EEM) and
enters applet configuration mode.
applet-name—Name of the applet file.