Cisco Systems A9014CFD Router User Manual


 
40-4
Cisco ASR 901 Series Aggregation Services Router Software Configuration Guide
OL-23826-09
Chapter 40 Digital Optical Monitoring
Examples
Example: Displaying Detailed Transceiver Information
This example shows how to display detailed transceiver information:
Router# show interfaces transceiver detail
mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
A2D readouts (if they differ), are reported in parentheses.
The threshold values are calibrated.
High Alarm High Warn Low Warn Low Alarm
Temperature Threshold Threshold Threshold Threshold
Port (Celsius) (Celsius) (Celsius) (Celsius) (Celsius)
--------- ----------------- ---------- --------- --------- ---------
Gi0/10 33.9 85.0 75.0 0.0 -5.0
Gi0/11 32.8 85.0 75.0 0.0 -5.0
High Alarm High Warn Low Warn Low Alarm
Voltage Threshold Threshold Threshold Threshold
Port (Volts) (Volts) (Volts) (Volts) (Volts)
--------- ----------------- ---------- --------- --------- ---------
Gi0/10 3.25 3.70 3.59 3.09 3.00
Gi0/11 3.23 3.70 3.59 3.09 3.00
High Alarm High Warn Low Warn Low Alarm
Current Threshold Threshold Threshold Threshold
Port (milliamperes) (mA) (mA) (mA) (mA)
--------- ----------------- ---------- --------- --------- ---------
Gi0/10 533.3 N/A N/A N/A N/A
Gi0/11 391.1 N/A N/A N/A N/A
Optical High Alarm High Warn Low Warn Low Alarm
Transmit Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
--------- ----------------- ---------- --------- --------- ---------
Gi0/10 -4.5 -3.5 -4.0 -9.5 -10.0
Gi0/11 -5.5 -3.5 -4.0 -9.5 -10.0
Optical High Alarm High Warn Low Warn Low Alarm
Receive Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
--------- ----------------- ---------- --------- --------- ---------
Gi0/10 -5.2 0.0 0.0 -17.0 -17.1
Gi0/11 -7.5 0.0 0.0 -17.0 -17.1