IBM SC30-3681-08 Saw User Manual


 
Set
Use the set command to set the maximum number of tags per second, the
timestamp feature, or to set tracing options.
Syntax:
set
pin...
remote-logging...
timestamp...
trace...
pin
max_traps
Use the set pin command to set the pin parameter to the maximum
number of traps that can be sent on a per-second basis. Internally, the pin
resets every tenth of a second. (One tenth of the number (
max_traps
)is
sent every tenth of a second.)
remote-logging
Use the set remote-logging command to configure remote logging options.
When these options are configured from the monitoring environment, the
changes take effect immediately, and return to their previously configured
settings when the device is rebooted.
Syntax:
set remote-logging
on
off
facility...
level...
no-msgs
remote_ip_addr...
source_ip_addr ...
local_id
on Turns remote logging on. Remote logging is now enabled to allow
any messages selected by the remote command to be actively
logged.
off Turns remote logging off. All messages selected by the ’remote’
command will be prevented from being logged.
facility
Specifies a value that, in combination with the
level
value, is used
by the syslog daemon in the remote workstation to determine where
to log messages. This value is used for all remotely-logged ELS
messages unless you specify a different value for a particular ELS
event, range, group, or subsystem with the remote command.
These are all possible syslog facility values:
log_auth
log_authpriv
log_cron
log_daemon
ELS Configuration Commands (Talk 6)
Chapter 13. Configuring and Monitoring the Event Logging System (ELS) 177
|
|