IBM SC30-3681-08 Saw User Manual


 
Enable
Use the enable command to turn on data transfer for an entire relay group or a
specific relay port.
Syntax:
enable group
group#
port
group
group#
Allows transfer of BSC Relay frames to or from the specified group.
Example: enable group 1
port Allows transfer of BSC Relay frames to or from the specified local port.
Example: enable port
Group number: [1]? 2
Local or Remote: [local]? remote
Group number
The group number of the port that you want to enable.
Local or Remote
Specifies whether to enable the local or remote port.
Default value: local
List (for network BSC)
Use the list command to display the configuration of a specific BSC interface.
Syntax:
list
Example:
list
Maximum frame size in bytes: 2048
Encoding: NRZI
Idle State: Sync
Clocking: Internal
Cable type: V.35 DCE
Speed (bps): 2048000
Code: ASCII
Link EOT: No
Number of pairs of SYNs: 1
Maximum frame size in bytes
Maximum frame size that can be sent over the link. The maximum frame
size must be large enough to accommodate the largest frame and the 15
byte BRLY header.
Encoding
The transmission encoding scheme for the serial interface. Scheme is NRZ
(non-return to zero) or NRZI (non-return to zero inverted).
Idle State
The data link idle state: sync or mark.
Clocking
The type of clocking: internal, external.
Configuring and Monitoring BSC Relay
Chapter 40. Configuring and Monitoring BSC Relay 571
|
|
|
|
||
||
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|