IBM SC30-3681-08 Saw User Manual


 
Circuit Config>set calls outbound
Circuit Config>set calls inbound
Note: For WAN Restoral operations or another dial-on-demand application,
you should set up the circuit for either inbound or outbound calls.
5. Specify the timeout period for the circuit.
Use the set idle command. If there is no traffic over the circuit for this
specified time period, the dial circuit hangs up. To configure the circuit as a
dedicated circuit, set the idle timer to zero. To configure the circuit to dial on
demand, set the idle timer to a value other than zero. The range is 0 to 65535
and the default is 60 seconds. For example:
Circuit Config>set idle
Idle timer (seconds, 0 means always active) [60]? 0
Note: For WAN Restoral or WAN Reroute operations you must set the idle
time to 0.
6. Optionally, you can delay the time between when a call is established and the
initial packet is sent.
Use the set selftest-delay command. Setting a selftest delay can prevent
initial packets from being dropped. If your modems take extra time to
synchronize, adjust this delay. For example:
Circuit Config>set selftest-delay
Selftest delay(milli-seconds,0 means no delay)[150]?200
7. Set the inbound address name.
Use the set inbound command. You need to use this command only if you set
up the circuit for both inbound and outbound calls and if the router’s
destination address is different from the destination address that the remote
router dials. For example, the numbers would be different if one of the routers
must go through a PBX, international, or inter-LATA exchange. For example:
Circuit Config>set inbound
Assign destination inbound address name []? newyork
The inbound address name must match one of the names that you defined
using the add v25-bis-address command.
8. Set the duplexing mode for the circuit using the set duplex command.
9. Set the encoding mode for the circuit using the set encoding command.
10. Optionally, you can enter the configuration process for the data-link layer
protocol that is running on the dial circuit (PPP or Frame Relay). Use the
encapsulator command. For example:
Circuit Config>encapsulator
Using V.25bis
582