IBM SC30-3681-08 Saw User Manual


 
Add bandwidth %
The amount of bandwidth utilization at which the software will try to
add a new link.
Valid Values: 1to99
Default Value: 90
Drop bandwidth %
The amount of bandwidth utilization at which the software will
remove a link from the MP bundle.
Valid values: 1to99
Default value: 70
Bandwidth test interval (sec)
The time, in seconds, after which the software will check the
bandwidth utilization to determine whether to add or drop a link
from the bundle.
Valid Values: 10 to 200 seconds
Default Value: 15
calls Specifies whether this MP interface will initiate outbound calls, only accept
outbound calls, or participate in both types of calls.
Valid values: inbound, outbound, or both
Default value: inbound
Note: If you specify outbound or both, the software will request the net
number of the dedicated MP link that will place the first call.
Example:
set calls outbound
Dialout MP link net for this MP net []? 4
idle Specifies the time period in seconds that an interface can have no protocol
traffic at which the MP interface will end calls on all the links.
Valid Values: 0 to 65535
Default Value: 0
mp parameters
Prompts you to enter the maximum and minimum fragment sizes and the
maximum number of active links.
Example:
set mp parameters
Max frag size [750]? 675
Min frag size [375]? 300
Max number of active links [2]? 4
Max frag size
Specifies the largest of number of bytes of data a packet can
contain before the packet is fragmented to be sent over MP links.
Valid Values: 100 to 3 000
Default Value: 750
Configuring MP
518
MRS V3.2 Software User’s Guide
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|