Invalid Packets Received
Displays the number of invalid X.25 packets received from the network.
Switched Circuits Open
Displays the number of switched circuits currently open.
Frame Layer Counters
Provides statistics generated from Frame Layer counters.
Information Frames
Displays the number of X.25 Information frames the interface has
transmitted and received.
X.25 Physical Layer Counters
Provides statistics generated from Physical Layer counters.
RX Bytes
Display the number of bytes received by the Physical layer.
TX Bytes
Displays the number of bytes transmitted by the Physical layer.
V.24 circuit Nicknames State
The circuits, control signals, pin assignments and their state (ON or OFF).
Note: The symbol---inmonitoring output indicates that the value or state
is unknown.
Line speed
The transmit clock rate.
Last port reset
The length of time since the last port reset.
Input frame errors:
CRC error
The number of packets received that contained checksum errors
and as a result were discarded.
Alignment
The number of packets received that were not an even multiple of 8
bits in length and as a result were discarded.
Too short
The number of packets that were less than 2 bytes in length and as
a result were discarded.
Too long
The number of packets that were greater than the configured size,
and as a result were discarded.
Aborted frame
The number of packets received that were aborted by the sender or
a line error.
DMA/FIFO overrun
The number of times the serial interface card could not send data
fast enough to the system packet buffer memory to receive them
from the network.
Configuring the X.25 Network Interface
358