group
group#
Displays the configuration of a specified group.
Set
Use the set command to configure the BSC interface parameters.
Syntax:
set cable
clocking [internal or external]
code [ebcdic or ascii]
encoding [nrz or nrzi]
eotlink [yes or no]
frame-size
idle [sync or mark]
speed
bps
syns
number
cable Sets the cable used on the serial interface. The options are:
v RS-232 DTE
v RS-232 DCE
v V35 DTE
v V35 DCE
v V36 DTE
v X21 DTE
v X21 DCE
Use a DTE cable when you are attaching the router to some type of DCE
device (for example, a modem or a DSU/CSU).
A DCE cable is used when the router is acting as the DCE and providing
the clocking for direct attachment.
clocking [internal or external]
Configures the BSC link’s clocking. To connect to a modem or DSU,
configure clocking as external. To connect directly to another DTE device,
use a DCE cable, set the clocking to internal, and configure the clock
speed. For internal clocking, you must enter a valid line speed in the range
2400 - 2048000 bits per second.
Example:
set clocking internal
code [ebcdic or ascii]
Specifies the code type that is used by this BSC device.
Default value: ebcdic
encoding [
nrz
or
nrzi
]
Configures the BSC interface’s encoding scheme as NRZ (Non-Return to
Zero) or NRZI (Non-Return to Zero Inverted). NRZ is the default.
Configuring and Monitoring BSC Relay
Chapter 40. Configuring and Monitoring BSC Relay 573
|
|
|
|
|
||
||
||
||
||
||
||
||
||
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|