IBM SC30-3681-08 Saw User Manual


 
range
subsystem
event
subsystem.event#
Causes the specified message (
subsystem.event#
) to be logged to the
message buffer.
group
groupname
Allows messages that were previously added to the specified group to be
logged to the message buffer.
range
subsystemname first_event_number last_event_number
Where
first_event_number
is the number of the first event in the specified
event range, and
last_event_number
is the number of the last event of the
specified event range.
Causes the messages that are in the specified range for the specified
subsystem to be logged to the message buffer.
Example:
log range gw 19 22
Causes the messages in events gw.19, gw.20, gw.21, and gw.22 to be
logged to the message buffer.
subsystem
subsystemname
Allows messages associated with the specified subsystem to be logged to
the message buffer.
Nolog
Use the nolog command to remove messages from the defined list of messages
that are logged to the message buffer.
Syntax:
nolog
event
group
range
subsystem
event
subsystem.event#
Causes the specified message (
subsystem.event#
) not to be logged to the
message buffer.
group
groupname
Allows messages that were previously added to the specified group not to
be logged to the message buffer.
range
subsystemname first_event_number last_event_number
Where
first_event_number
is the number of the first event in the specified
event range, and
last_event_number
is the number of the last event of the
specified event range.
Causes the messages that are in the specified range for the specified
subsystem not to be logged to the message buffer.
Example:
log range gw 19 22
ELS Configuration Commands (Talk 6)
Chapter 13. Configuring and Monitoring the Event Logging System (ELS) 185
||
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
||
||
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|