Tektronix 071-0590-00 Welding System User Manual


 
Reference
GB1400 User Manual 3-35
Test Process Set Up
The TEST Menu contains the following six selections:
LENGTH: Test length: hours, minutes, seconds.
MODE: Test timing mode: Timed, Untimed, or Repeat.
REPORT: Test reporting mode: None, Print On Error, or Both.
THRESH: Threshold for the TES (threshold errored second) result.
SQUEL: On Error report squelch after 10 consecutive seconds: yes or no.
PRINT: Use this function to print current Test results immediately.
If you want to collect TEST results, you must set LENGTH and MODE before
you begin a test. And if you are using a printer you should set the REPORT
parameter as desired. Note that On Error reports can generate a lot of paper, so
select On Error or Both with caution. Setup of the other parameters in the TEST
Menu are optional.
Procedure
1. Press F1 to access the Menu system.
2. Select the TEST Menu (F2).
3. Within the TEST Menu, set up:
a. LENGTH (F2) and
b. MODE (F3).
4. And, if you are using a printer, set up the REPORT parameter (F4).
5. Press MORE (F1) to see the next page of the TEST Menu. Review the
setup of the THRES (F2) and SQUEL (F3) parameters. Change if
necessary.
NOTE: Setting SQUEL (squelch) to ON is recommended.
6. Press the F1 key multiple times to exit the Menu system.
See later in this chapter for more information of setting up the TEST Menu.