res_es?
Results Errored Seconds. This command returns the total number of errored seconds
counted, either in the current test interval so far or in the previous test interval, depending
on the setup of TEST PREV and the current test state.
Min. Abbr. res_es?
Returns <NR1>
Example res_es? (command)
RES_ES 384 (response)
res_es_per?
Results Error-Free Seconds Percentage. This command returns the percentage of
errored seconds calculated, either in the current test interval so far or in the previous test
interval, depending on the setup of TEST PREV and the current test state.
Min. Abbr. res_es_?
Returns <NR2>
Example res_es_per? (command)
RES_ES_PER 89.35 (response)
res_los?
Results Loss of Signal Seconds. This command returns the total number of seconds
counted, that contained a loss of signal event, either in the current test interval so far or in
the previous test interval, depending on the setup of TEST PREV and the current test
state.
Min. Abbr. res_l?
Returns <NR1>
Example res_los? (command)