Remote Commands
C-72 GB1400 User Manual
histry_phase?
History Phase. Returns a character string indicating the state of the PHASE error
history indicator.
Min. Abbr. histry_ph?
Returns [on | off]
Example histry_phase? (command)
HISTRY_PHASE ON (response)
histry_power?
History Power. Returns a character string indicating the state of the POWER Loss
history indicator.
Min. Abbr. histry_po?
Returns [on | off]
Example histry_power? (command)
HISTORY_POWER OFF (response)
histry_stat?
History Status Query. This command returns a summary of the Analyzer's front panel
status. The response will be in the form of multiple message units separated by
semicolons.
Min. Abbr. histry_st?
Returns Window error rate <NR3>
Totalize error rate <NR3>
Received clock frequency <NR3>
Sync Lock status [on | off]
History status indicators [on | off]
Example histry_stat (command)
WIN_RATE 1.5E-03; (response)
TOTAL_RATE 3.7E-06;
CLOCK_FREQ 701.47E+6;
SYNC OFF;
HISTRY_SYNC ON;
HISTRY_BITS ON;
HISTRY_PHASE OFF;
HISTRY_POWER OFF