Tektronix 071-0590-00 Welding System User Manual


 
Remote Commands
C-80 GB1400 User Manual
WINDOW Setup Commands
win_bit_len [v]
Windows Bit Length. Sets BER window bit length parameter to 1 x 10
v
bits. This
parameter determines window length when WIN_MODE is set to BITS.
Min. Abbr. win_bit_
Arguments v <NR1>, in the range 8, 9, ..., 16.
Example win_bit_len 15
win_bit_len?
Windows Bit Length Query. Returns the value v, indicating that the BER window bit
length parameter is set to 1 x 10
v
bits.
Min. Abbr. win_bit_?
Returns <NR1>
Example win_bit_len? (command)
WIN_BIT_LEN 15 (response)
win_bits?
Window Bits. Returns the total number of bits evaluated so far in the BERwindow
interval.
Min. Abbr. win_bits?
Returns <NR1>
Example win_bits? (command)
WIN_BITS 49098302 (response)
win_error?
Windows Errors. Returns the total number of bit errors counted so far in the BER
window current or previous interval.
Min. Abbr. win_e
Returns <NR1>
Example win_error? (command)
WIN_ERROR 27 (response)