Tektronix 071-0590-00 Welding System User Manual


 
Reference
GB1400 User Manual 3-69
Test View Previous (VIEW-PRE)
Format:
F1:ESC F4:SET
(result name)(count) (%)
Menu: TEST
Function Name: VIEW-PRE
Instruments: Analyzer only
Options: None required. This is a standard feature.
Application: Use this function to view results from the last completed test.
Parameters: This is an immediate function. After selecting VIEW-PRE
use the pattern up/down keys to scroll through the results
shown below.
START (test start time), STOP (test stop time), ELAPSED
(duration of test), TTL BIT (total number of bits in interval),
TTL ERR (total number of bit errors counted), AVE ERROR
RATE (BER of TEST interval), CUR ERROR RATE (BER
of WINDOW interval), US (Unavailable Seconds), SES
(Severely Errored Seconds), TES (Threshold Errored
Seconds), ES (Errored Seconds), EFS (Error Free Seconds),
DM (Degraded Minutes), SIG LOSS SEC (seconds in which
a loss of signal has occurred), SYNC LOSS SEC (seconds in
which a loss of pattern synchronization has occurred),
PHASE ERR SEC (seconds in which a phase error has
occurred).