Tektronix 071-0590-00 Welding System User Manual


 
Remote Commands
GB1400 User Manual C-17
*tst?
Self Test. Causes the instrument to perform a self test and return the result. A result of
0 means the self test was successful. A return of any other value means the self test was
not successful. The GB1400 self test is limited in scope.
Min. Abbr. *tst?
Returns 0 (if successful)
Example *tst? (command)
0 (indicates successful self test)
*wai
Wait. This command forces the instrument to stop processing any additional commands
until all pending operations are completed.
Min. Abbr. *wai
tse [v] (Analyzer Only)
Test Status Enable. This command sets the Test Status Enable Register to the bit
sequence corresponding to v, where v is a decimal number in the range 0 to 255.
Min. Abbr. tse
Argument n: <NR1>, in the range 0 to 255.
Example tse 255
(sets the TSR to 11111111 binary)
tse? (Analyzer Only)
Test Status Enable (Register) Query. This command returns a decimal number
representing the current contents of the Test Status Enable Register (TSER).
Min. Abbr. tse?
Returns <NR1>, in the range 0 to 255.
Example tse? (command)
TSE 255 (response)