Tektronix 071-0590-00 Welding System User Manual


 
Remote Commands
C-52 GB1400 User Manual
res_pha_es?
Results Phase Errored Seconds. This command returns the total number of phase
errored seconds counted, either in the current test interval so far or in the previous test
interval, depending on the setup of TEST PREV and the current test state.
Min. Abbr. res_p?
Returns <NR1>
Example res_pha_es? (command)
RES_PHA_ES 591 (response)
res_ses?
Results Severely Errored Seconds. This command returns the total number of
severely errored seconds counted, either in the current test interval so far or in the
previous test interval, depending on the setup of TEST PREV and the current test state.
Min. Abbr. res_ses?
Returns <NR1>
Example res_ses? (command)
RES_SES 1290121 (response)
res_ses_per?
Results Severely Errored Seconds Percentage. This command returns the
percentage of severely errored seconds counted, either in the current test interval so far
or in the previous test interval, depending on the setup of TEST PREV and the current
test state.
Min. Abbr. res_ses_?
Returns <NR2>
Example res_ses_per? (command)
RES_SES_PER 27.70 (response)