Tektronix 071-0590-00 Welding System User Manual


 
Remote Commands
GB1400 User Manual C-79
test_thres [v]
Test Threshold. Used to set the test error rate threshold to the value: 1 x 10
-v
. This
threshold determines which seconds are counted as Threshold Errored Seconds (TES).
It also determines when On-Error reports are generated.
Min. Abbr. test_t
Arguments v <NR1>, in the range 2, 3, ..., 16. That is the test
error
rate threshold may be set in the range 10
-2
to 10
-16
.
Example test_thres 12
test_thres?
Test Threshold Query. Returns the value v, indicating that the current test error rate
threshold is set to 1 x 10
-v
.
Min. Abbr. test_t?
Returns <NR1>
Example test_thres? (command)
TEST_THRES 12 (response)
indicating that the test error rate threshold
is set to 1 x 10
-12
.