Tektronix 071-0590-00 Welding System User Manual


 
Remote Commands
C-62 GB1400 User Manual
data_thres?
Data Threshold Query. Returns the current threshold voltage for the Analyzer DATA
input.
Min. Abbr. data_thre?
Returns <NR2>
Example data_thres? (command)
DATA_THRES -1.50 (response)
rdata_del_up and
rdata_del_dn
Reference Data Delay Up/Down (Default). This command pair is used to increment
(rdata_del_up) or decrement (rdata_del_dn) the current REF DATA delay by the default
increment of 0.1 nSec.
Min. Abbr. rdata_del_u
rdata_del_d
Arguments none
Examples rdata_del_up
rdata_del_dn
rdata_del_up [v] and
rdata_del_dn [v]
Reference Data Delay Up/Down. This command pair is used to increment
(rdata_del_up) or decrement (rdata_del_dn) the current REF DATA delay by v, where v
is in <NR3> format and may be set in the range 0.1 nSec to 3.99 nSec in 0.1 nSec steps.
Min. Abbr. rdata_del_u
rdata_del_d
Argument v: <NR3>, 0.10E-9 to 3.90E-9 in 0.10E-9 steps.
Examples rdata_del_up 1.00E-9
rdata_del_dn 1.00E-9