Remote Commands
C-44 GB1400 User Manual
Min. Abbr. data_off_u
data_off_d
Arguments none
Example data_off_up
data_off_up [v] and
data_off_dn [v]
Data Offset Up, Data Offset Down. This command pair is used to increment or
decrement the current baseline offset of the Generator data output by a specified step size
of [v] volts.
Min. Abbr. data_off_u
data_off_d
Arguments v: <NR2>, in the range 0.05 to 3.00, in steps of 0.05.
in the range 0.05 to 3.80 in 0.05 v steps (PECL option)
Example data_off_up 0.20
data_offset [v]
Data Offset. Sets the baseline offset of the Generator data output to a specified value of
[v] volts.
Min. Abbr. data_offs
Arguments v: <NR2>, in the range -2.00 to 1.00 in steps of 0.05.
in the range -2.00 to 1.80 in 0.05 v steps (PECL option)
Example data_offset -0.50
data_offset?
Data Offset Query. Returns the current baseline offset of the Generator data output in
terms of volts.
Min. Abbr. data_offs?
Returns <NR2>
Example data_offset? (command)
DATA_OFFSET -0.50 (response)