test_mode [untimed|timed|repeat]
Test Mode. Sets the test timing mode. The test once started, will stop and start
according to the mode.
Min. Abbr. test_m
Arguments untimed: after test start, a test interval will continue until a test
stop command is received, or the test is stopped manually from
the front panel, or power loss.
timed: after a test start, a test interval will stop automatically
after test length has elapsed, front panel key, remote command or
power loss.
repeat: after test start, a test interval will stop and then restart
automatically after test length has elapsed. This process will
continue until a test stop command is received, or testing is
stopped manually from the front panel, or by power loss.
Example test_mode timed
test_mode?
Test Mode Query. Returns the current Analyzer test timing mode.
Min. Abbr. test_m?
Returns [untimed|timed|repeat]
Example test_mode?
TEST_MODE TIMED
test_prev [current|previous]
Test Previous. Sets test_prev parameter to "current" or "previous". This parameter
determines whether responses to results query commands will be based on the current
interval or the previous interval.
Min. Abbr. test_pre
Arguments current: Test status commands will return results from
the current test interval
previous: Test status commands will return results from
the previous test interval
Example test_prev current