Tektronix 071-0590-00 Welding System User Manual


 
Pattern Editing Software
H-4 GB1400 User Manual
directory is still there and is not corrupted. If it is not there, copy the MLPE.INI
file from the MLPE directory to the WINDOWS directory. See if the program
runs properly. If it is there, it may possibly be corrupted. Rename the file that is
there to MLPE.SAV and copy the MLPE.INI file from the MLPE directory to the
WINDOWS directory. if the program runs properly, delete the MLPE.SAV file
from the WINDOWS directory.
At any time, should any part of the program be corrupted or accidentally deleted,
the program can be re-installed.
RS-232 Cabling
If you are using the Editor with a gigaBERT700/1400/1600 and want to use RS-
232 to Upload or Download patterns, your RS-232 cable should be wired as
shown below:
gigaBERT RS-232 pin number 25 pin Comm Port 9 pin Comm Port
2 2 3
3 3 2
4 4 7
5 5 8
6 6 6
7 7 5
All other pins are not used.
GPIB
This program has been designed to use National Instruments GPIB hardware. It
may not work, or work properly with other brands of hardware.
Program Exclusivity
When running the Tektronix Pattern Editor it is suggested that there be no other
Windows programs running at the same time in the background. The normal
baud rate for operating the program is 9600 baud and other applications that are
running at the same time could cause some transferred data to be dropped. To
avoid lost data, close any other background applications so that Windows can
devote maximum time to the Editor.